YMGI OUTDOOR CONDENSER UNIT SEER 21 WMMS-36CH-V2B(59)4
Item#: WMMS-36CH-V2B(59)4
Brand: YMGI
Free Shipping Sold by: waterheatingsystem.com
Seller | Seller Ratings | Info | Price | Go to Store |
---|---|---|---|---|
www.cheapestairconditioner.com | Trusted Seller | In Stock New | $249 | Go to Store |
www.ductlessairconditionerunit.com | Trusted Seller | In Stock New | $249 | Go to Store |
www.throughthewallairconditioningunits.com | Trusted Seller | In Stock New | $249 | Go to Store |
www.airconditionersfilters.com | Trusted Seller | In Stock New | $249 | Go to Store |
www.centralairconditionersreviews.com | Trusted Seller | In Stock New | $249 | Go to Store |
Product Details
YMGI Specifications: DC Inverter Mini Split Heat Pump-Multiple Zone-(59)4 Outdoor Units 21SEER | ||
Model | Units | WMMS-36CH-V2B(59)4 |
Cooling Capacity Rating-Standard Comp. Speed | Btu/h | 24000 |
Min./Max. Cooling Capacity | Btu/h | 7500 / 33000 |
Heating Capacity Rating-Standard Comp. Speed | Btu/h | 26000 |
Min./Max. Heating Capacity | Btu/h | 7500 / 27978 |
Max. Allowed IDU Qty./Capacity Total | # / Btu/h | 3 / 36,000 |
EER W/W, (Btu/h)/W | W/W | 3.66 / 12.5 |
COP W/W, (Btu/h)/W | W/W | 3.72 / 12.70 |
SEER / HSPF | - | 21.00 / 10.50 |
Air Flow Volume | CFM | 2354 |
Sound Pressure / Power Level | dB(A) | 59 / 69 |
Power Supply | V/Ph/Hz | 208-230/1/60 |
Power Cable Conductor Minimum Size | AWG | AWG12, Following NEC |
Recommended HVAC Type Circuit Breaker Size | Amp. | 30 |
Power Input Cooling / Heating / Rated | KW | 1.92 / 2.05 / 3.60 |
Current Input Cooling / Heating / Rated | A | 8.35 / 8.90 / 15.97 |
Compressor Type, Model | - | Inverter Rotarty, LD QXAS- D23zX090B |
Compressor Capacity / Input | W | 7250 / 2550 |
Compressor RLA / LRA | A | 15.82 / - |
Compressor Thermal Protector KINGERSONS | - | Exterior 1NT11L—6233 |
Compressor Crankcase Heater | W | 40 |
Compressor Oil Type, Charge | -, OZs | RB68EP, 33.4 |
De-Ice/Snow Heater Power Input | W | 96 |
De-Ice/Snow Heater Current | A | 0.4 |
Fan Type / Qty. / Diameter-Height | - | Axial-flow / 1 /D550-H66mm |
Motor Model / Type | - | LW92K-ZL, DC |
Motor Insulation Class, Safe Class | - | B or E, IPX4 |
Fan Motor Drive Type, Speed | - | Director Drive, 800 |
Fan Motor Power Output / Input | W | 90 / - |
Motor Full Load Amp (FLA) | A | - |
Condenser Materials | - | Aluminum Fin-Copper Tube |
Permissible Operating Pressure for the Discharge/Suction Sides | PSI | 600 / 360 |
High/Low Pressure Overload Protector | PSI | 580 / - |
Cooling Operation Ambient Temperature Range | F | 0 ~ 118 |
Heating Operation Ambient Temperature Range | F | -4 ~ 75 |
Defrosting Method of Heat Pump in Low Temperature Ambient |
-- | Automatic Reversing, Fan Cycling |
Pressure Maitenance Method in Low Temperature Cooling |
-- | Automatic Fan Speed Control, Cycling |
Overload Protector | - | Current+Temperature |
Designed for Climate Type, Moisture Protection | - | T1, IPX4 |
Refrigerant, Charge | LBs | R410A, 4.8 |
Metering Device KINGERSONS | - | Electronic expansion valve |
Flare/Nut Valve Size-Liquid | Inch | 1/4, 1/4, 1/4 |
Flare/Nut Valve Size-Gas | Inch | 3/8, 3/8, 3/8 |
Min. Allowed Copper Line Length/Unit | Ft. | 15 |
Max. Allowed Copper Line Length- outdoor to last indoor unit |
Ft. | 65 |
Max. Elevation Difference Allowed- outdoor unit is below all indoor units |
Ft. | 35, Oil Trap is Not Needed |
Max. Elevation Difference Allowed- outdoor unit is above indoor units |
Ft. | 35, Oil Trap is Suggested Every 18' |
Max. Copper Line Length (all together) | Ft. | 195 |
No Additional Refrigerant Needs to be Added, If Copper Line Length Total is Less Than | Ft. | 100 |
Refrigerant Charge Rate, If Needed, by Weight/Ft. of Extra Liquid Line Length |
Ozs/Ft. | 2.32 |
Dimension of Unit Outline (W×D×H) | Inch | 38.6x16.8x31.1 |
Dimension of Package (W×D×H) | Inch | 42.6x19.2x33.7 |
Weight-Net / Gross | LBs | 153 / 164 |
Loading Quantity (20’/40GP/40HQ) | Units | 44 / 96 / 144 |
Related Product
-
KSIL009H119 Klimaire 9000btu/h 19 SEER Brand: Klimaire
More Brands
-
Wall Thermostat for Premaire PTAC Brand: Hvac Accessories