Panasonic CSKE36NKU CUKE36NKU 33000 BTU Single Zone Heat Pump Wall Mounted SEER 16

Item#: CSKE36NKU CUKE36NKU

Brand: Panasonic

Free Shipping Sold by: waterheatingsystem.com

Seller Seller Ratings Info Price Go to Store
www.cheapestairconditioner.com Trusted Seller In Stock New $249 Go to Store
www.ductlessairconditionerunit.com Trusted Seller In Stock New $249 Go to Store
www.throughthewallairconditioningunits.com Trusted Seller In Stock New $249 Go to Store
www.airconditionersfilters.com Trusted Seller In Stock New $249 Go to Store
www.centralairconditionersreviews.com Trusted Seller In Stock New $249 Go to Store

Note: Your submitted review is subject to the license terms set out in our Terms of Use. By submitting your review, you acknowledge that you have the authority to do so and that your review does not violate another party's copyright or intellectual property rights

Product Details

SPECIFICATIONS:

Type Wall Mounted
Unit Heat Pumps
Indoor Unit CS-KE36NKU
Outdoor Unit CU-KE36NKU
Performance & Electrical Ratings
Capacity Cooling (Btu/h) 30,600 (10,900~30,600)
Capacity Heating (Btu/h) 33,000 (14,000~33,000)
Moisture Removal - High - Pints/H 9.57
Dry Air Flow - High -CFM 630
Dry Air Flow - Medium -CFM 530
Dry Air Flow - Low -CFM 412
SEER - Cooling 16
EER - Cooling 9.3
HSPF - Heating 9
Power Supply V, Phase, Hz 230/208V, 1PH, 60Hz
Running Amps - Cooling - A 16.5 (5 ~ 16.5) / 18.0
Running Amps - Heating - A 15.3 (4.5 ~ 15.3) / 16.3
Power Input - Cooling - W 3,290
Power Input - Heating - W 3070
Back-up Heater kW
Fuse or Circuit Breaker Capacity - A 35
Features
Controls Microprocessor
Low Ambient Control Built-in 0°F
Wireless Remote Controller Included
Wired Remote Controller (optional) CZ-RD515U & CZ-RC515UA
Fan Speeds Hi / Me / Lo & Auto
Timer 1hr OFF and 24-hr Program
Air Deflection - Horizontal Manual
Air Deflection - Vertical Automatic
Air Filter Washable
Refrigerant R-410A
Refrigerant Control Electric Expansion Valve
Operation Sound - In(Hi / Me / Lo/ Qt) dB-A 49 / 44 / 39
Operation Sound - Outdoor (Hi) dB-A 55
Refrigerant Piping -Type Flare
Refrigerant Piping - Discharge - inches 3/8"
Refrigerant Piping - Suction - inches 5/8"
Refrigerant Pipe Length - ft Max. 164
Elevation Difference - Outdoor Above - ft Max. 100
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
Elevation Difference - Outdoor Below - ft Max. 50
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
Dimensions & Weight
Height (inches) Indoor Unit: 11-3/16"
Outdoor Unit: 35-13/16"
Width (inches) Indoor Unit: 41-15/16"
Outdoor Unit: 37-1/32"
Depth (inches) Indoor Unit: 9-1/16"
Outdoor Unit: 13-3/8"
Net Weight (lbs.) Indoor Unit: 32
Outdoor Unit: 185

 

Description:

Panasonic’s Ductless Split Heat Pump products offer wide versatility in solving your cooling and heating requirements for a single or multiple rooms. The Indoor unit(evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit(condenser) via refrigerant lines & inter-unit wiring through a 3-1/2” opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted systems, with whisper quiet operations, quality & reliability you can count on.

Microprocessor-Controlled Operation
Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.

Wireless Remote Control
Panasonic’s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.

Self-Diagnosing Function
Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)

Dry Mode
By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.

3 Fan Speeds and Automatic Fan Operation
Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.

Air Sweep Control
The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.

Louver Control
Louver can be manually set to the desired angle by remote control.

Automatic Heating and Cooling Changeover
After setting the temperature and functions you desire, just relax. If the room temperature is higher than the set temperature, cooling operation begins. If the room temperature is lower than the set temperature, heating operation begins. During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature. (Single Zone Heat Pump unit only)

Hot Start Heating System
Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cold blasts at the beginning while the heat pump is warming up. (Heat pump unit only)

24-hour Clock with ON/OFF Program Timer
The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.

1-hour OFF Timer
When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically.

Automatic Restart Function after Power Failure
This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.

Low Ambient Operation
Operates in cooling mode as low as 0°F

Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.

R-410A
This refrigerant blend has been the industry choice for being friendlier to the environment

Quiet Mode
LOW, low fan speed for extra quiet operation.